Troubleshooting¶
General¶
The Context parameters in platform are greyed out and cannot be changed
Run vsi::__::fix_platform_context in VSI TCL console (the platform canvas must be open)
When importing the platform file into an existing system context tab, encountered with the error message “failed import. The design “platform” is not a valid vsi_system design”.Follow the below steps
Select the “Sources” tab.
Select the < system_context > from the list in the Sources tab.
Import Platform
.
Modifying TCP server settings for data type and package size is not editable in input and output blocks
uncheck and re-check the check box for the input and output, then the fields will be editable.
when creating platform for a particular speed grade part using the create_zync_platform.tcl script the default part value is set to xc7z020clg400-2.
Edit vsi_create_zynq_platform.tcl file to the corresponding part of the speed grade.
User constraints is not been applied due to the default user constraints in Vivado.
After encountering with the error edit the file mentioned in the error according to the required constraints to the user.
For example: When a Project with x86 and PCIe is created user constraints. Disable the 4 constraints regarding the pcie lane location and add the required ones.
Crashing of the software executable due to insufficient FIFO size.
For example: The system consists of a x86 PC and a FPGA connected over PCIe. The system consists 2 tcp Servers and a customized VHDL IP, see image. When more than 4096Bytes are sent to the hardware at ones, the Software executable crashed.
In the generated vivado Project, open the Blockdesign, search for the vc707 block and open. There is a FIFO Block located near the input and output of the custom VHDL IP. Adjust the FIFO size to be larger then the max. possible input packet size.
Runtime / Generated Context¶
The first step should be to enable logging for runtime. VSI Runtime supports a modular logging system that can be turned on by setting the environment variables
VSI_LOG_LVL=info and VSI_LOG_COMPS=all
. For the full set of valid values, see logging section
Java Specific¶
Swig Director Error
Python Specific¶
Swig Director Error
Check the data size is properly set inside each software wizard. Sometimes, an IP upgrade can null out the values.
Check that the data type is correctly set. For valid types that are supported, check here
Cannot import
Make sure that all the sources are present in the current directory. In addition, a
_<context_name>.so
should be present.
Build errors on
Flow->Build Software Contexts
When switching between a cross compile and host compile for a context, even when “clean and rebuild” is selected, the switched context still has a toolchain file and CMake may attempt to use it when compiling. The fix is to delete the context directory under
<project>/vsi_auto_gen/sw
and regenerate the context usinggenerate system